65% TYPICAL, FULL LOAD CONDITION AT 115/230 VAC INPUT.
POWER GOOD SIGNAL
ON DELAY TIME 100 ~ 500 ms, OFF DELAY TIME 1ms.
HOLD UP TIME
17ms AT 25C FULL LOAD CONDITION AT 115/230 VAC INPUT.
OPERATING TEMPERATURE RANGE
0c ~ 50c
REMOTE ON/OFF CONTROL
THE POWER SUPPLY OUTPUT SHALL BE ENABLED WITH AN ACTIVE-LOW TTL SIGNAL. WHEN TTL SIGNAL IS LOW, THE DC OUTPUTS ARE TO BE ENABLED. WHEN TTL SIGNAL IS HIGH OR OPEN CIRCUITED, THE DC OUTPUTS ARE TO BE DISABLED.
OVER POWER PROTECTION
AT 115/230 VAC INPUT THE POWER SUPPLY WILL SHUT DOWN ALL DC OUTPUT WITH IN 100% ~ 150% OF FULL LOAD.
OVER VOLTAGE PROTECTION
+5V ~ 7.0V, +12V1, +12V2 ~ 15.6V, +3.3V ~ 4.3V.
EMI REQUIREMENT
FCC PART 15 SUB PART J CLASS B AT SYSTEM LOAD, CISPR 22 CLASS B, CE, BSMI.
SAFETY
UL, N, S, D, FI.
DIMENSION
150 (D) x 140 (W) x 86 (H) mm.
COOLING
ONE 120mm DC FAN
PASSIVE POWER FACTOR CORRECTION
EN 61000-3-2: 1995+A1+A2: 1998, CLASS D.(FOR 230V ONLY)
OUTPUT CHARACTERISTICS:
OUTPUT VOLTAGE
OUTPUT CURRENT
REGULATIONLINE
OUTPUT
MIN [A]
MAX [A]
LOAD
LINE
RIPPLE MAX [P-P]
NOISE MAX [P-P]
+5V
1
25
+/- 5%
+/- 1%
50mV
50mV
+12V1
1
15
+/- 5%
+/- 1%
120mV
120mV
+12V2
1
15
+/- 5%
+/- 1%
120mV
120mV
+3.3V
1
28
+/- 5%
+/- 1%
50mV
50mV
-5V
0
0.1
+/- 10%
+/- 1%
100mV
100mV
-12V
0
0.8
+/- 10%
+/- 1%
120mV
120mV
+5VSB
0
2.0
+/- 5%
+/- 1%
50mV
50mV
1.
MAXIMUM CONTINUOUS COMBINED LOAD ON +5V AND +3.3V OUTPUTS SHALL NOT EXCEED 150W. +12V1 AND +12V OUTPUTS SHALL NOT EXCEED 25A.
2.
MAXIMUM CONTINUOUS COMBINED LOAD ON +5V, +3.3V AND +12V1, +12V2 OUTPUTS SHALL NOT EXCEED 330W.
3.
MAXIMUM CONTINUOUS TOTAL DC OUTPUT POWER SHALL NOT EXCEED 350W.